<LOGO>
FM Transmitter Measurement Report
Created: 2025-04-15 01-15-58
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.10 MHz 4/5, 34 dBuV CauseCom
Pilot RDS Phase Difference
8.0 kHz 3.9 kHz -85 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
16 kHz 72 kHz 1087 1,0120
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
3,6 dBr 4,36 dBr 5,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"CauseCom" FE46 9 (Varied) 0 0 1 1 --:--
RT
" "
AF EON
-
FM Scope Station: 93.10 MHz, signal: 4/5 (34 dBuV) Max at: 72 kHz MIN: 16 kHz % above 76 kHz: 1,0120 Acquired: 2025/04/15 1:14:54 Total samples: 1087 Equivalent time: 0:00:54 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 10 20 30
FM Scope MAX: 5,2 dBr MIN: 3,6 dBr AVE: 4,36 dBr % above 10,2 dBr: 0,0 Last value: 4,7 dBr (2025/04/15 1:14:54) Station: 93.10 MHz, signal: 4/5 (34 dBuV) 01:08 01:09 01:10 01:11 01:12 01:13 01:14 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality